  panasonic corporation automation controls business unit industrial.panasonic.com/ac/e/ lq (alq) asctb92e 201206-t ordering information types standard packing: carton 100 pcs., case 500 pcs. 1 form a/1 form c 10a small power relays lq relays (alq) nominal coil voltage 1 form a 1 form c part no. part no. 5v dc alq305 alq105 6v dc alq306 alq106 9v dc alq309 alq109 12v dc alq312 alq112 18v dc alq318 alq118 24v dc ALQ324 alq124 * protective construction: flux-resistant type rohs compliant features 1. miniature size and small: 10(w) 20(l) 16(h) mm .394(w) .787(l) .630(h) inch 2. compact with high capacity: 1 form a and 1 form c, 10 a 3. ambient temperature: ?0 c to +85 c ?0 f to 185 f 4. high surge voltage: 8,000 v between contacts and coil 5. high breakdown voltage: 4,000 v between contacts and coil typical applications 1. household appliances air conditioners, refrigerators, fan heaters, microwave ovens, inverter and hot water units ne w contact arrangement 1: 1 form c 3: 1 form a alq coil insulation class nil: f: class b insulation class f insulation nominal coil voltage (dc) 05: 5v, 06: 6v, 09: 9v, 12: 12v, 18: 18v, 24: 24v
panasonic corporation automation controls business unit industrial.panasonic.com/ac/e/ lq (alq) asctb92e 201206-t rating 1. coil data 2. speci?ations * speci?ations will vary with foreign standards certi?ation ratings. notes: *1. this value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. wave is standard shock voltage of 1.2 50 s according to jec-212-1981 *3. the upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. refer to usage, transport and storage conditions in notes. *4. when using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% v for each 1 c 33.8 f with 20 c 68 f as a reference) and use a coil impressed voltage that is within the maximum applied voltage range. contact arrangement nominal coil voltage pick-up voltage (at 20 c 68 f ) drop-out voltage (at 20 c 68 f ) nominal operating current [ 10%] (at 20 c 68 f ) coil resistance [ 10%] (at 20 c 68 f ) nominal operating power (at 20 c 68 f ) max. applied voltage 1 form a 5v dc 75%v or less of nominal voltage (initial) 5%v or more of nominal voltage (initial) 40.0ma 125 ? 200mw 180% of nominal voltage (at 20 c 68 f ) 130% of nominal voltage (at 85 c 185 f )* 4 6v dc 33.3ma 180 ? 9v dc 22.2ma 405 ? 12v dc 16.7ma 720 ? 18v dc 11.1ma 1,620 ? 24v dc 8.3ma 2,880 ? 1 form c 5v dc 75%v or less of nominal voltage (initial) 5%v or more of nominal voltage (initial) 80.0ma 62.5 ? 400mw 150% of nominal voltage (at 20 c 68 f ) 110% of nominal voltage (at 85 c 185 f )* 4 6v dc 66.7ma 90 ? 9v dc 44.4ma 202.5 ? 12v dc 33.3ma 360 ? 18v dc 22.2ma 810 ? 24v dc 16.7ma 1,440 ? characteristics item speci?ations contact arrangement 1 form a 1 form c contact resistance (initial) max. 100m ? (by voltage drop 6 v dc 1 a) contact material agni type rating nominal switching capacity (resistive load) 5 a 30 v dc, 10 a 125 v ac, 5 a 250 v ac n.o. side: 10 a 125 v ac, 5 a 250 v ac, 5 a 30 v dc n.c. side: 3 a 125 v ac, 2 a 250 v ac, 1 a 30 v dc max. switching power (resistive load) 150 w, 1,250 va n.o. side: 150 w, 1,250 va n.c. side: 30 w, 500 va max. switching voltage 250 v ac max. switching current n.o.: 10 a (125v ac), n.c.: 3 a (125v ac) nominal operating power 200 mw 400 mw min. switching capacity (reference value)* 1 100 ma, 5 v dc electrical characteristics insulation resistance (initial) min. 1,000 m ? (at 500 v dc) measurement at same location as ?reakdown voltage section. breakdown voltage (initial) between open contacts 1,000 vrms for 1 min. (detection current: 10 ma) 750 vrms for 1 min. (detection current: 10 ma) between contact and coil 4,000 vrms for 1 min. (detection current: 10 ma) temperature rise (coil)* 4 max. 45 c 113 f (by resistive method, nominal coil voltage applied to the coil; contact carrying current: 10a, at 85 c 185 f ) surge breakdown voltage* 2 (between contact and coil) 8,000 v (initial) operate time (at nominal voltage) (at 20 c 68 f ) max. 20 ms (excluding contact bounce time.) (initial) release time (at nominal voltage) (at 20 c 68 f ) max. 20 ms (excluding contact bounce time, with diode) (initial) mechanical characteristics shock resistance functional 1 form a: 294 m/s 2 , 1 form c: 196 m/s 2 (half-wave pulse of sine wave: 11 ms; detection time: 10 s.) destructive 980 m/s 2 (half-wave pulse of sine wave: 6 ms.) vibration resistance functional 10 to 55 hz at double amplitude of 1.6 mm (detection time: 10 s.) destructive 10 to 55 hz at double amplitude of 2.0 mm expected life mechanical min. 10 7 (at 180 times/min.) conditions conditions for operation, transport and storage* 3 ambient temperature: ?0 c to +85 c ?0 f to +185 f humidity: 5 to 85% r.h. (not freezing and condensing at low temperature) max. operating speed 20 times/min. (at nominal switching capacity) unit weight approx. 7 g .25 oz
panasonic corporation automation controls business unit industrial.panasonic.com/ac/e/ lq (alq) asctb92e 201206-t 3. expected electrical life condition: resistive load, at 20 c 68 f , at 20 times/min., with diode reference data type switching capacity no. of operations 1 form a (at 20 times/min.) 10 a 125 v ac 5 a 250 v ac 5 a 30 v dc 5 10 4 5 10 4 10 5 1 form c (at 20 times/min.) n.o. 10 a 125 v ac 5 a 250 v ac 5 a 30 v dc 5 10 4 5 10 4 10 5 n.c. 3 a 125 v ac 2 a 250 v ac 1 a 30 v dc 2 10 5 2 10 5 10 5 1.-(1) max. switching capacity (1 form a type) 1.-(2) max. switching capacity (1 form c type) 2. life curve ambient temperature: room temperature 1,000 ac resistive load 10010 250 100 10 5 1 contact voltage, v contact current, a 1,00025010010 100 10 5 3 2 1 contact voltage, v contact current, a ac resistive load n.o. side ac resistive load n.c. side 125v ac resistive load 250v ac resistive load 1086420 100 10 1 contact current, a life, 10 4 3.-(1) coil temperature rise (1 form a type) contact carrying current: 5 a, 10 a measured portion: inside the coil 3.-(2) coil temperature rise (1 form c type) contact carrying current: 5 a, 10 a measured portion: inside the coil 4.-(1) ambient temperature characteristics (1 form a type) contact carrying current: 5 a, 10 a 180160140120100 coil applied voltage, %v 70 60 50 40 30 20 10 0 te mperature rise, c 10 a at 70 c 5 a at 70 c 5 a at 85 c 10 a at 85 c 160150140130120110100 coil applied voltage, %v 70 60 50 40 30 20 10 0 temperature rise, c 10 a at 70 c 10 a at 85 c 5 a at 85 c 5 a at 70 c 020304 05060708090 ambient temperature, c 400 300 200 100 coil applied voltage, %v 1 2 3 4 5 6 7 4.-(2) ambient temperature characteristics (1 form c type) contact carrying current: 5 a, 10 a 1 allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130 c 266 f ) (carrying current: 5 a) 2 allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130 c 266 f ) (carrying current: 10 a) 3 allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115 c 239 f ) (carrying current: 5 a) 4 allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115 c 239 f ) (carrying current: 10 a) 5 pick-up voltage with a hot-start condition of 100%v on the coil (carrying current: 10 a) 6 pick-up voltage with a hot-start condition of 100%v on the coil (carrying current: 5 a) 7 pick-up voltage 0203 0405060708090 ambient temperature, c 400 300 200 100 coil applied voltage, %v 1 2 3 4 5 6 7
panasonic corporation automation controls business unit industrial.panasonic.com/ac/e/ lq (alq) asctb92e 201206-t dimensions (mm inch ) safety standards note) csa standard: certi?d by c-ul item ul/c-ul (recognized) vde (certi?d) file no. contact rating file no. contact rating 1 form a e43028 10a 125v ac 5a 277v ac 5a 30v dc 4fla/4lra 277v ac 1 / 6 hp 125v ac 1 / 6 hp 277v ac 40032836 5a 250v ac (cos =1.0) 10a 250v ac (cos =1.0) 10a 250v ac (cos =0.4) 5a 30v dc (0ms) 1 form c e43028 10a 125v ac 5a 277v ac 5a 30v dc 4fla/4lra 277v ac 1 / 6 hp 125v ac 1 / 6 hp 277v ac 3a 125v ac 2a 277v ac 1a 30v dc 40032836 5a 250v ac (cos =1.0) 10a 250v ac (cos =1.0) 10a 250v ac (cos =0.4) 5a 30v dc (0ms) 3a 250v ac (cos =0.4) the cad data of the products with a cad data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ external dimensions 1 form a 1 form c 20 .787 10.16 .400 7.62 .300 7.62 .300 10 .394 7.62 .300 15.6 .614 4.2 .165 0.4 .016 0.5 dia. .020 dia. 0.3 .012 0.3 .012 0.8 .031 20 .787 10.16 .400 5.08 .200 10 .394 7.62 .300 15.6 .614 4.2 .165 0.4 .016 0.5 dia. .020 dia. 0.3 .012 0.3 .012 0.3 .012 2.54 .100 7.62 .300 0.8 .031 0.8 .031 schematic (bottom view) 1 form a 1 form c coil com n.o. coil com n.o. n.c. pc board pattern (bottom view) 1 form a1formc tolerance: 0.1 .004 4-1.3 dia. 7.62 7.62 10.16 4-.051 dia. .300 .300 .400 5-1.3 dia. 7.62 7.62 10.16 2.54 5-.051 dia. .300 .300 .400 .100 cad data dimension: less than 1mm .039inch : min. 1mm .039inch less than 5mm .197 inch : min. 5mm .197 inch : gener al toler ance 0.2 .008 0.3 .012 0.4 .016
panasonic corporation automation controls business unit industrial.panasonic.com/ac/e/ lq (alq) asctb92e 201206-t notes usage, transport and storage conditions 1) temperature: ?0 to +85 c ?0 to +185 f 2) humidity: 5 to 85% rh (avoid freezing and condensation.) the humidity range varies with the temperature. use within the range indicated in the graph below. 3) atmospheric pressure: 86 to 106 kpa temperature and humidity range for usage, transport, and storage 4) condensation condensation forms when there is a sudden change in temperature under high temperature and high humidity conditions. condensation will cause deterioration of the relay insulation. 5) freezing condensation or other moisture may freeze on the relay when the temperatures is lower than 0 c 32 f . this causes problems such as sticking of movable parts or operational time lags. 6) low temperature, low humidity environments the plastic becomes brittle if the relay is exposed to a low temperature, low humidity environment for long periods of time. solder and cleaning conditions 1) please obey the following conditions when soldering automatically. (1) preheating: within 120 c 248 f (solder surface terminal portion) and within 120 seconds (2) soldering iron: 260 c 5 c 500 f 41 f (solder temperature) and within 6 seconds (soldering time) 2) do not use ultrasonic cleaning. this will adversely affect relay characteristics. when cleaning the relay, please use alcoholic solvents. cautions for use 1) for precautions regarding use and explanations of technical terminology, please refer to our web site. (panasonic-electric-works.net/ac) 2) to ensure good operation, please keep the voltage on the coil ends to 5% (at 20 c 68 f ) of the rated coil operation voltage. also, please be aware that the pick-up voltage and drop-out voltage may change depending on the temperature and conditions of use. 3) keep the ripple rate of the nominal coil voltage below 5%. 4) the cycle lifetime is de?ed under the standard test condition speci?d in the jis c 5442 standard (temperature 15 to 35 c 59 to 95 f , humidity 25 to 75%). check this with the real device as it is affected by coil driving circuit, load type, activation frequency, activation phase, ambient conditions and other factors. also, be especially careful of loads such as those listed below. (1) when used for ac load-operating and the operating phase is synchronous. rocking and fusing can easily occur due to contact shifting. (2) highly frequent load-operating when highly frequent opening and closing of the relay is performed with a load that causes arcs at the contacts, nitrogen and oxygen in the air is fused by the arc energy and hno 3 is formed. this can corrode metal materials. three countermeasures for these are listed here. ?incorporate an arc-extinguishing circuit. ?lower the operating frequency ?lower the ambient humidity 5) this value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. 6) heat, smoke, and even a ?e may occur if the relay is used in conditions outside of the allowable ranges for the coil ratings, contact ratings, operating cycle lifetime, and other speci?ations. therefore, do not use the relay if these ratings are exceeded. 7) if the relay has been dropped, the appearance and characteristics should always be checked before use. 8) incorrect wiring may cause unexpected events or the generation of heat or ?mes. 85 5 humidity, %rh tolerance range (avoid condensation when used at temperatures higher than 0 c 32 f ) (avoid freezing when used at temperatures lower than 0 c 32 f ) 850?0 +185+32?0 te mperature, c f
mouser electronics authorized distributor click to view pricing, inventory, delivery & lifecycle information: panasonic: ? alq105? alq106? alq109? alq112? alq118? alq124? alq305? alq306? alq309? alq312? alq318? ALQ324


▲Up To Search▲   

 
Price & Availability of ALQ324

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X